Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Metric Locking Assembly

Specifications

Shaft Size

25 mm

d

0.984 in

D

1.969 in

L

0.669 in

L1

0.787 in

L2

1.024 in

Mt

329 ft-lbs

Fax

8,027 lbs.F

Ps

32322 psi

Ph

16161 psi
DN1 2.867 in

Locking Screws Quantity

9

Locking Screws Size

M6 x 18

Ma-Locking Screws

10 ft-lbs

dB-Locking Screws

M8

Hub Machining Tolerance

0.002 in

Shaft Machining Tolerance

-0.002 in

Weight

0.50 lb

UPC Code

044861075920

Competitor Part Number

Alternate Part Number

101928972 2735386 87793683 B401025 PL025X050 AS RfN 7012 25 x 50 SLD 1500 MM 25X50 TLK 200 25X50
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform