Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 300 mm

d

N/A 11.811 in

D

N/A 14.764 in

L

N/A 2.362 in

L1

N/A 2.638 in

L2

N/A 3.346 in

L3

N/A 4.055 in

Mt

N/A 111,726 ft-lbs

Fax

N/A 227,028 lbs.F

Ps

N/A 21,585 psi

Ph

N/A 17268 psi
DN1 N/A 22.123 in

Locking Screws Quantity

N/A 18

Locking Screws Size

N/A M18 x 50

Ma-Locking Screws

N/A 299 ft-lbs

Hub Machining Tolerance

N/A 0.004 in

Shaft Machining Tolerance

N/A -0.003 in

Weight

N/A 80.00 lb

UPC Code

N/A 044861058244

Competitor Part Number

Alternate Part Number

N/A 101740 103041796 T301300
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform