CAD (0)
  • Cart is empty
Single-taper, self-centering design with mounting flange for use in through-bored components with smaller pitch/outside diameters. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 60 mm

d

N/A 2.362 in

D

N/A 3.031 in

D1

N/A 3.858 in

D2

N/A 4.094 in

L

N/A 2.165 in

L1

N/A 2.874 in

L2

N/A 3.189 in

L3

N/A 3.504 in

Mt

N/A 2,051 ft-lbs

Fax

N/A 20,836 lbs.F

Ps

N/A 10,805 psi

Ph

N/A 8420 psi
DN1 N/A 3.663 in

Locking Screws Quantity

N/A 9

Locking Screws Size

N/A M8 x 22

Ma-Locking Screws

N/A 30 ft-lbs

Hub Machining Tolerance

N/A 0.003 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 4.88 lb

UPC Code

N/A 044861077764

Competitor Part Number

Alternate Part Number

N/A 101934025 2735377 PL060X077 TF SLD 1900 MM 60X77 T8060 TLK 110 60X77
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.