CAD (0)
  • Cart is empty
Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 500 mm

d

N/A 19.685 in

D

N/A 23.819 in

L

N/A 3.780 in

L1

N/A 4.016 in

L2

N/A 4.961 in

Mt

N/A 587,543 ft-lbs

Fax

N/A 716,332 lbs.F

Ps

N/A 25539 psi

Ph

N/A 21107 psi
DN1 N/A 39.620 in

Locking Screws Quantity

N/A 44

Locking Screws Size

N/A M24 x 90

Ma-Locking Screws

N/A 738 ft-lbs

dB-Locking Screws

N/A M30

Hub Machining Tolerance

N/A 0.006 in

Shaft Machining Tolerance

N/A -0.006 in

Weight

N/A 160.00 lb

UPC Code

N/A 044861087732
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform