Print Back
Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 40 mm

d

N/A 1.575 in

D

N/A 2.559 in

L

N/A 0.669 in

L1

N/A 0.886 in

L2

N/A 1.122 in

L3

N/A 1.358 in

Mt

N/A 658 ft-lbs

Fax

N/A 10,024 lbs.F

Ps

N/A 25,227 psi

Ph

N/A 15524 psi
DN1 N/A 3.667 in

Locking Screws Quantity

N/A 8

Locking Screws Size

N/A M6 x 20

Ma-Locking Screws

N/A 10 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 0.90 lb

UPC Code

N/A 044861074848

Competitor Part Number

Alternate Part Number

N/A 101936131 2735156 7003 ECOLOC 40 x 65 B301040 PL040X065 FL SLD 1350 MM 40X65 SLD 1850 MM 40X65 TLK 132 40X65
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform