Print Back
Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 35 mm

d

N/A 1.378 in

D

N/A 2.362 in

L

N/A 0.669 in

L1

N/A 0.787 in

L2

N/A 1.024 in

Mt

N/A 614 ft-lbs

Fax

N/A 10,703 lbs.F

Ps

N/A 30783 psi

Ph

N/A 17957 psi
DN1 N/A 3.604 in

Locking Screws Quantity

N/A 12

Locking Screws Size

N/A M6 x 18

Ma-Locking Screws

N/A 10 ft-lbs

dB-Locking Screws

N/A M8

Hub Machining Tolerance

N/A 0.003 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 0.60 lb

UPC Code

N/A 044861075289

Competitor Part Number

Alternate Part Number

N/A 101936139 2735391 87793725 B401035 PL035X060 AS RfN 7012 35 x 60 SLD 1500 MM 35X60 TLK 200 35X60
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform