Single-taper, self-centering design with mounting flange for use in through-bored components with smaller pitch/outside diameters. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Locking Assembly

Specifications

Shaft Size

4 in

d

4.000 in

D

4.921 in

D1

6.024 in

D2

6.299 in

L

2.756 in

L1

3.701 in

L2

4.213 in

L3

4.685 in

Mt

11,351 ft-lbs

Fax

68,108 lbs.F

Ps

16389 psi

Ph

13321 psi
DN1 6.677 in

Locking Screws Quantity

12

Locking Screws Size

M12 x 30

Ma-Locking Screws

107 ft-lbs

Hub Machining Tolerance

0.003 in

Shaft Machining Tolerance

-0.003 in

Weight

12.00 lb

UPC Code

044861043370

Competitor Part Number

Alternate Part Number

104995080 7569313 B802400 TLK 110 4
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.