Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Metric Locking Assembly

Specifications

Shaft Size

48 mm

d

1.890 in

D

3.150 in

L

0.787 in

L1

1.043 in

L2

1.358 in

L3

1.673 in

Mt

678 ft-lbs

Fax

8610 lbs.F

Ps

9,573 psi

Ph

5657 psi
DN1 3.812 in

Locking Screws Quantity

7

Locking Screws Size

M8 x 25

Ma-Locking Screws

16 ft-lbs

Hub Machining Tolerance

0.002 in

Shaft Machining Tolerance

-0.002 in

Weight

1.60 lb
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform