Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Metric Locking Assembly

Specifications

Shaft Size

110 mm

d

4.331 in

D

6.102 in

L

1.024 in

L1

1.299 in

L2

1.772 in

Mt

9,656 ft-lbs

Fax

53,513 lbs.F

Ps

32020 psi

Ph

22724 psi
DN1 10.640 in

Locking Screws Quantity

14

Locking Screws Size

M12 x 30

Ma-Locking Screws

89 ft-lbs

dB-Locking Screws

M14

Hub Machining Tolerance

0.004 in

Shaft Machining Tolerance

-0.003 in

Weight

5.10 lb

UPC Code

044861086742

Competitor Part Number

Alternate Part Number

103218344 2748070 B401110 PL110X155 AS RfN 7012 110 x 155 SLD 1500 MM 110X155 TLK 200 110X155
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform