Print Back
Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Metric Locking Assembly

Specifications

Shaft Size

18 mm

d

0.709 in

D

1.850 in

L

0.669 in

L1

0.886 in

L2

1.122 in

L3

1.358 in

Mt

95 ft-lbs

Fax

3304 lbs.F

Ps

11459 psi

Ph

4352 psi
DN1 2.142 in

Locking Screws Quantity

5

Locking Screws Size

M6 x 20

Ma-Locking Screws

7 ft-lbs

Hub Machining Tolerance

0.002 in

Shaft Machining Tolerance

-0.002 in

Weight

0.60 lb
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform