Print Back
Single-taper, self-centering design with mounting flange for use in through-bored components with smaller pitch/outside diameters. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Metric Locking Assembly

Specifications

Shaft Size

120 mm

d

4.724 in

D

6.102 in

D1

7.362 in

D2

7.795 in

L

3.543 in

L1

4.528 in

L2

5.039 in

L3

5.512 in

Mt

17,876 ft-lbs

Fax

90,811 lbs.F

Ps

14390 psi

Ph

11140 psi
DN1 7.858 in

Locking Screws Quantity

16

Locking Screws Size

M12 x 30

Ma-Locking Screws

107 ft-lbs

Hub Machining Tolerance

0.003 in

Shaft Machining Tolerance

-0.003 in

Weight

21.00 lb

UPC Code

044861077474

Competitor Part Number

Alternate Part Number

103214261 2735416 7110 ECOLOC 120 x 155 SLD 1900 MM 120X155 T8120 TLK 110 120X155
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.