CAD (0)
  • Cart is empty
Single-taper, self-centering design with mounting flange for use in through-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Locking Assembly

Specifications

Shaft Size

N/A 1 5/8 in

d

N/A 1.625 in

D

N/A 2.953 in

D1

N/A 3.287 in

L

N/A 0.787 in

L1

N/A 1.043 in

L2

N/A 1.358 in

L3

N/A 1.673 in

Mt

N/A 1,097 ft-lbs

Fax

N/A 16,206 lbs.F

Ps

N/A 33,596 psi

Ph

N/A 18489 psi
DN1 N/A 4.569 in

Locking Screws Quantity

N/A 7

Locking Screws Size

N/A M8 x 25

Ma-Locking Screws

N/A 30 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 1.70 lb

UPC Code

N/A 044861074954

Competitor Part Number

Alternate Part Number

N/A 101958532 2735119 7006 ECOLOC 1.625 x 2.953 87793428 B602110 PL1-5/8 AE SLD 1450 IN 1-5/8 SLD 1750 IN 1-5/8 TLK 133 1 5/8
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform