Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Metric Locking Assembly

Specifications

Shaft Size

38 mm

d

1.496 in

D

2.559 in

L

0.669 in

L1

0.886 in

L2

1.122 in

L3

1.358 in

Mt

324 ft-lbs

Fax

5305 lbs.F

Ps

8703 psi

Ph

5077 psi
DN1 3.036 in

Locking Screws Quantity

8

Locking Screws Size

M6 x 20

Ma-Locking Screws

7 ft-lbs

Hub Machining Tolerance

0.002 in

Shaft Machining Tolerance

-0.002 in

Weight

0.80 lb
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform