Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 340 mm

d

N/A 13.386 in

D

N/A 16.732 in

L

N/A 2.835 in

L1

N/A 3.071 in

L2

N/A 3.858 in

Mt

N/A 227,400 ft-lbs

Fax

N/A 407,715 lbs.F

Ps

N/A 28502 psi

Ph

N/A 22802 psi
DN1 N/A 29.243 in

Locking Screws Quantity

N/A 36

Locking Screws Size

N/A M20 x 70

Ma-Locking Screws

N/A 428 ft-lbs

dB-Locking Screws

N/A M24

Hub Machining Tolerance

N/A 0.006 in

Shaft Machining Tolerance

N/A -0.005 in

Weight

N/A 69.00 lb

UPC Code

N/A 044861087312

Competitor Part Number

Alternate Part Number

N/A TLK 200 340X425