Single-taper, self-centering design with mounting flange for use in through-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Locking Assembly

Specifications

Shaft Size

2 11/16 in

d

2.688 in

D

4.331 in

D1

4.685 in

L

0.945 in

L1

1.201 in

L2

1.594 in

L3

1.988 in

Mt

3,405 ft-lbs

Fax

30,403 lbs.F

Ps

31,759 psi

Ph

19708 psi
DN1 6.927 in

Locking Screws Quantity

8

Locking Screws Size

M10 x 30

Ma-Locking Screws

61 ft-lbs

Hub Machining Tolerance

0.002 in

Shaft Machining Tolerance

-0.002 in

Weight

3.80 lb

UPC Code

044861074862

Competitor Part Number

Alternate Part Number

103213155 2735126 7006 ECOLOC 2.688 x 4.331 PL2-11/16 AE SLD 1450 IN 2-11/16 SLD 1750 IN 2-11/16 T602211 TLK 133 2 11/16
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform