CAD (0)
  • Cart is empty
Single-taper, self-centering design with mounting flange for use in through-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 140 mm

d

N/A 5.512 in

D

N/A 7.480 in

D1

N/A 7.835 in

L

N/A 1.339 in

L1

N/A 1.614 in

L2

N/A 2.165 in

L3

N/A 2.717 in

Mt

N/A 15,779 ft-lbs

Fax

N/A 68,706 lbs.F

Ps

N/A 24,701 psi

Ph

N/A 18201 psi
DN1 N/A 11.487 in

Locking Screws Quantity

N/A 9

Locking Screws Size

N/A M14 x 40

Ma-Locking Screws

N/A 170 ft-lbs

Hub Machining Tolerance

N/A 0.003 in

Shaft Machining Tolerance

N/A -0.003 in

Weight

N/A 12.00 lb

UPC Code

N/A 044861004845

Competitor Part Number

Alternate Part Number

N/A 104995556 7006 ECOLOC 140 x 190 7569293 B601140 PL140X190 AE SLD 1450 MM 140X190 SLD 1750 MM 140X190 TLK 133 140X190
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform