Single-taper, self-centering design with mounting flange for use in through-bored components with smaller pitch/outside diameters. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 110 mm

d

N/A 4.331 in

D

N/A 5.512 in

D1

N/A 6.614 in

D2

N/A 6.850 in

L

N/A 2.756 in

L1

N/A 3.701 in

L2

N/A 4.213 in

L3

N/A 4.685 in

Mt

N/A 12,290 ft-lbs

Fax

N/A 68,108 lbs.F

Ps

N/A 15137 psi

Ph

N/A 11894 psi
DN1 N/A 7.226 in

Locking Screws Quantity

N/A 12

Locking Screws Size

N/A M12 x 30

Ma-Locking Screws

N/A 107 ft-lbs

Hub Machining Tolerance

N/A 0.003 in

Shaft Machining Tolerance

N/A -0.003 in

Weight

N/A 15.00 lb

UPC Code

N/A 044861077627

Competitor Part Number

Alternate Part Number

N/A 103196053 2735415 7110 ECOLOC 110 x 140 SLD 1900 MM 110X140 T8110 TLK 110 110X140
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.