Single-taper, self-centering design with mounting flange for use in through-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Locking Assembly

Specifications

Shaft Size

1 in

d

1.000 in

D

1.688 in

D1

1.875 in

L

0.591 in

L1

0.754 in

L2

0.984 in

L3

1.181 in

Mt

3,518 in-lbs

Fax

7,037 lbs.F

Ps

31,582 psi

Ph

18,715 psi
DN1 2.627 in

Locking Screws Quantity

8

Locking Screws Size

M5 x 18

Ma-Locking Screws

89 in-lbs

Hub Machining Tolerance

0.001 in

Shaft Machining Tolerance

-0.001 in

Weight

0.40 lb

UPC Code

044861046616
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.