Print Back
Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Metric Locking Assembly

Specifications

Shaft Size

120 mm

d

4.724 in

D

6.496 in

L

1.024 in

L1

1.299 in

L2

1.772 in

L3

2.244 in

Mt

5244 ft-lbs

Fax

26527 lbs.F

Ps

8,993 psi

Ph

6527 psi
DN1 8.104 in

Locking Screws Quantity

9

Locking Screws Size

M12 x 35

Ma-Locking Screws

55 ft-lbs

Hub Machining Tolerance

0.003 in

Shaft Machining Tolerance

-0.002 in

Weight

7.20 lb
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform