Metric Locking Assembly

Specifications

Shaft Size

140 mm

d

5.512 in

D

7.480 in

L

1.339 in

L1

1.496 in

L2

1.969 in

Mt

19,312 ft-lbs

Fax

84,091 lbs.F

Ps

30233 psi

Ph

22277 psi
DN1 12.871 in

Locking Screws Quantity

22

Locking Screws Size

M12 x 35

Ma-Locking Screws

89 ft-lbs

dB-Locking Screws

M14

Hub Machining Tolerance

0.004 in

Shaft Machining Tolerance

-0.004 in

Weight

8.20 lb

UPC Code

044861087688

Competitor Part Number

Alternate Part Number

101936602 2748073 B401140 PL140X190 AS RfN 7012 140 x 190 SLD 1500 MM 140X190 TLK 200 140X190