Print Back
Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Locking Assembly

Specifications

Shaft Size

N/A 2 7/8 in

d

N/A 2.875 in

D

N/A 4.528 in

L

N/A 0.945 in

L1

N/A 1.201 in

L2

N/A 1.594 in

L3

N/A 1.988 in

Mt

N/A 1,923 ft-lbs

Fax

N/A 16,052 lbs.F

Ps

N/A 9,981 psi

Ph

N/A 6237 psi
DN1 N/A 5.592 in

Locking Screws Quantity

N/A 8

Locking Screws Size

N/A M10 x 30

Ma-Locking Screws

N/A 33 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 4.00 lb
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform