Print Back
Single-taper, self-centering design with mounting flange for use in through-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 19 mm

d

N/A 0.748 in

D

N/A 1.850 in

D1

N/A 2.047 in

L

N/A 0.669 in

L1

N/A 0.886 in

L2

N/A 1.122 in

L3

N/A 1.358 in

Mt

N/A 195 ft-lbs

Fax

N/A 6,265 lbs.F

Ps

N/A 33,193 psi

Ph

N/A 13418 psi
DN1 N/A 2.517 in

Locking Screws Quantity

N/A 5

Locking Screws Size

N/A M6 x 20

Ma-Locking Screws

N/A 13 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 0.60 lb

UPC Code

N/A 044861040539

Competitor Part Number

Alternate Part Number

N/A 104998209 7006 ECOLOC 19 x 47 7569300 PL019X047 AE SLD 1450 MM 19X47 SLD 1750 MM 19X47 T601019
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform