CAD (0)
  • Cart is empty
Single-taper, self-centering design with mounting flange for use in through-bored components with smaller pitch/outside diameters. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Locking Assembly

Specifications

Shaft Size

N/A 3/4 in

d

N/A 0.750 in

D

N/A 1.063 in

D1

N/A 1.693 in

D2

N/A 1.929 in

L

N/A 0.709 in

L1

N/A 1.280 in

L2

N/A 1.555 in

L3

N/A 1.791 in

Mt

N/A 157 ft-lbs

Fax

N/A 5,012 lbs.F

Ps

N/A 25013 psi

Ph

N/A 17648 psi
DN1 N/A 1.609 in

Locking Screws Quantity

N/A 4

Locking Screws Size

N/A M6 x 16

Ma-Locking Screws

N/A 13 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 0.70 lb

UPC Code

N/A 044861077313

Competitor Part Number

Alternate Part Number

N/A 101933654 2747995 B802012 SLD 1900 IN 3/4 TLK 110 3/4
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.