Single-taper, self-centering design with mounting flange for use in through-bored components with smaller pitch/outside diameters. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Locking Assembly

Specifications

Shaft Size

N/A 1 11/16 in

d

N/A 1.688 in

D

N/A 2.323 in

D1

N/A 3.150 in

D2

N/A 3.386 in

L

N/A 1.772 in

L1

N/A 2.441 in

L2

N/A 2.756 in

L3

N/A 3.071 in

Mt

N/A 1,302 ft-lbs

Fax

N/A 18,521 lbs.F

Ps

N/A 16433 psi

Ph

N/A 11938 psi
DN1 N/A 3.048 in

Locking Screws Quantity

N/A 8

Locking Screws Size

N/A M8 x 22

Ma-Locking Screws

N/A 30 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 2.70 lb

UPC Code

N/A 044861077085

Competitor Part Number

Alternate Part Number

N/A 103219246 2748008 SLD 1900 IN 1-11/16 T82111 TLK 110 1 11/16
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.